How to Choose the Right Sequencing Approach

Choosing a sequencing approach for plant, food safety or microbial work comes down to three questions: How large and complex is the genome? What quality of DNA can you extract? What analyses do you need afterward? This article outlines the sequencing and library preparation options for each application and how those three questions shape the choice.

When comparing plant genomics options, start with the platform. Illumina whole genome sequencing is the standard for resequencing and SNP discovery against an existing reference, but short reads cannot assemble through the long repeats common in plant genomes. For genomes without a reliable reference, PacBio HiFi sequencing resolves those repeats and structural variants and provides methylation data; 15-20x depth is recommended for resequencing and SNP discovery while 30-100x depth is recommended for publication-quality assemblies. Oxford Nanopore sequencing also adds long-range structure and methylation data, though with lower per-base accuracy. The best fit depends on whether you are resequencing known material or building a new reference. Extraction is the second criterion. Polysaccharides carried over from plant tissue interfere with long-read library preparation and are best removed during extraction with a CTAB or modified Nanobind protocol. While SeqCenter routinely performs high-molecular-weight extractions on cell lines, plant tissue is more complicated. Its fibrous cells are best extracted through intensive bead beating, which suits short-read sequencing. For long-read projects on fibrous tissue, SeqCenter recommends extracting DNA in your own lab, assessing fragment length and shipping on dry ice. When placing your order, request that SeqCenter confirm fragment size by QC before sequencing. Analysis is the third criterion. Diploid variant calling is available now, polyploid variant calling is planned for Q1 2027, and ultra-low-pass sequencing on Illumina and PacBio with imputation analysis will launch in 2027. Contact bioinfo@seqcenter.com for details on these upcoming services.

Crop genomics programs typically combine resequencing across breeding lines, long-read reference assemblies and targeted genotyping. Teams that prepare their own amplicon or genotyping-by-sequencing libraries can run them on dedicated Illumina flowcells, adding a PhiX spike-in for low-diversity amplicon pools. For trait expression, stranded RNA sequencing with polyA enrichment suits plant transcriptomes; at least three biological replicates per group, sequenced together, keep batch effects correctable. PacBio IsoSeq resolves full-length isoforms without assembly. For soil and rhizosphere studies, 16S or ITS amplicon sequencing compares taxa across sites, while shotgun metagenomics is better suited to detecting plant pathogens and functional gene sets.

For food safety, the core NGS option is whole genome sequencing of pure isolates, which supports strain typing, outbreak linkage and antimicrobial resistance profiling. Short-read assemblies are sufficient for most typing, while hybrid Nanopore and Illumina sequencing closes chromosomes and resolves plasmids. Analysis add-ons include resistance gene detection with AMRFinderPlus, average nucleotide identity and species identification. For facility environmental monitoring, 16S/ITS amplicon sequencing tolerates low-biomass swabs, while shotgun metagenomics also captures viruses and functional genes. SeqCenter accepts organisms up to BSL-2+ and holds no testing accreditations, so its services fit investigations, surveillance and monitoring rather than regulated release testing. High-volume programs can arrange typing analyses that follow their own methods, provided an existing tool can perform them; send inquiries to bioinfo@seqcenter.com.

A custom microbial genomics pipeline should run every isolate through the same documented steps: sequencing, assembly, annotation, then typing, resistance and variant analyses. Platform choice sets the ceiling on assembly quality. Short-read assemblies typically produce more than 100 contigs per genome, hybrid assemblies approach reference quality for clonal bacteria and fungi, and PacBio HiFi produces the most complete assemblies along with 4mC and 6mA methylation calls. SeqCenter’s bioinformatics catalog chains open-source tools that are applied per sample so large collections are processed with identical, reproducible parameters. These pipelines support both eukaryotic and microbial genetics work, such as confirming that engineered or evolved strains carry the intended mutation and are otherwise isogenic with the parent, through variant calling, insertion verification and copy number analysis. Analyses outside the catalog are accepted case by case when a peer-reviewed publication describes the method. As with any bioinformatic output, results are predictive and should be validated experimentally before publication.